Buy and Sell Used Industrial Refrigeration Equipment - T +31 (0)297 565 443 - info@comronbv.com

Freeze / cold rooms and Freeze / cold room installations
Brand   Type   kW    Description   Year   More info
DWM/Copeland / Helpman   storage / freeze Installation -60°C/-65°C, type of refrigerant: R23+R404A   14 kW   Used, very special low temperature DWM/Copeland/Helpman storage/freezing installation (cascade system) and consists of the following main components: • Cascade central compressor unit, consists of: 1 x semi-hermetic DWM low pressure compressor, working with refrigerant R23 at evaporating temperature of -68°C 2 x semi-hermetic high pressure compressors, working with refrigerant R404A at evaporating temperature -30°C • 2 x Helpman single sided blowing low temperature evaporators with each 2 pieces ventilators of 750W, electrical defrost, air flow 10.400m3/h, dimensions 210 x 110x 70 cm and weight 110kg • 1 x Helpman double sided blowing evaporator for the production room(sluice) -20°C ambient temp. with 3 ventilators of 250W, electrical defrost, air flow 5.400m3/h, dimensions 345 x 170 x 59cm, weight 325kg with a cooling capacity of 28kW at evaporating temperature of -30°Cl • 1 x Helpman air-cooled condenser with copper/seawater resistant fin coils • Switch-board • Under-pressure and over-pressure valves Mentioned cooling capacity is with the refrigerant R23+R404a at -68°C/-30°C, -30°C/+40°C. This installation is suitable for a freeze storage of approx. 600m3with a storage temperature of -60°C to -65°C, very suitable for tuna storage.
  2001   More information
Frigotronic / Copeland   HSB-CU-120/2 SCR used refrigerator/freezing equipment, type of refrigerant: R404A/507   20 kW   Nice used Cool/Freeze installation for cooling a cool or freeze room, equipped with the following main components: condensing unit for outdoor installation, consisting of air-cooled condenser, 2 pieces scroll compressor and control box. This unit will be delivered with 2 pieces of Goedhart cool / freeze evaporators type FC385BP502-7-230E with electric defrosting and with a fin spacing of 7 mm. Mentioned cooling capacity of 20 kW is at an evaporating temperature of -30°C with a refrigerant. R404a/507 Cooling capacity at an evaporating temperature of -10°C is approximately 40 kW.
  2006   More information
Bitzer   used freeze- and cold store installations   56 kW   Used and in very well condition: a complete Bitzer cool/freeze installation to cool a big cool or freeze room.
  2000   More information
Bitzer   HSN 7471-75-40R Bitzer storage freezing installation, type of refrigerant: R404A/All Freon   83 kW   Used and in very good maintained condition (always maintained by GEA) storage freezing installation, brand Bitzer/Goedhart. This storage freezing installation will be composed of the following main components: • 1 piece Bitzer screw package type HSN 7471-75-40R • Bitzer screw package is equipped with oil separator, air-cooled oil cooler, closed intercooler for subcooling liquid coupled to the eco. compressor, Bitzer liquid tank of 180L • Suction manifold with suction filter • Manometer set low/high pressure with all necessary safety devices • Complete control box with Eliwell step controller • 5 pieces Goedhart VCI-B-82508EF freeze storage evaporators with electric defrost • Cabero air-cooled condenser type ACHSD099MB / 2L-26D, year of 2016 Mentioned cooling capacity is with the refrigerant R404a/R507 at -30°C /+40°C. This installation is suitable for a deep-freeze storage of approx.. 4000m3 storage space with a storage temperature of -20°C.
  2005/2016   More information
Bitzer/Goedhart   used cool/ freeze installation, type of refrigerant: R507   100 kW   Used, in very good condition complete Bitzer/Goedhart cooling/freezing combination (very suitable for 0°C, -10°C, -20°C storage temperatures) and consists of the following main components: • 2 pieces Bitzer cool/freeze units with each: 2 pieces Bitzer 4P-15.2Y-40P compressors 1 piece 6J-33.2Y-40P compressor • 10 pieces Goedhart cooling/freezing evaporators, type VNS-65457 with electrical defrost and each 5 pieces WOODS ventilators 220V/310Watt • 1 piece Goedhart air-cooled condenser type KOAL-M66 710.6P with 2 separate sections • Switch-board Mentioned cooling capacity of 100kW is with the refrigerant R507 at evaporating temperature of -30°C. Cooling capacity at an evaporating temperature of -10°C is 248kW.
  2004   More information
Bitzer/Searle/GEA   complete cooling plant, type of refrigerant: R404A /All Freon   112 kW   Used complete Bitzer/ Searle/GEA cooling plant-/installation. This in very good condition complete cooling plant is composed of the following main components: • Bitzer piston package consists of 1 piece Bitzer piston compressor type 6H-35.2Y (frequency controlled at 60Hz) 1 piece Bitzer piston compressor type 4G-20.2Y Oil separator, Vertical liquid tank, high/low pressure gauges with all necessary safety devices • 3 pieces Searle/GEA dual-discharge blowing cooling-/freezing evaporators type LSR122-64-4D-EL, each with air volume 3,6m3/s, fin spacing 4mm, electrical defrost • 2 pieces Searle/GEA dual-discharge blowing cooling-/freezing evaporators type DSR100-4L each with air volume 1,7m3/s, fin spacing 4mm, electrical defrost • 1 piece Searle/GEA one-sided blowing cooling evaporator type DSR100-4L with air volume 2,7m3/s, fin spacing 4mm, electrical defrost • 1 piece Searle/GEA air-cooled condenser type MEC234-N604D AL • Complete control cabinet with Danfoss frequency controller Mentioned cooling capacity of 112kW is with the refrigerant R404 at -8°C/+45°C.
  2011   More information
Bitzer   used cold store installation   118 kW   Used and in very good condition: a complete refrigeration installation to cool a big cold room or corridor. The installation consists of the following main components: Bitzer 6F 50.2Y-40P tank aggregate, switch-board, separate Güntner condenser, 5 pieces two sided blowing Güntner evaporators. Mentioned cooling capacity is at 0°C evaporating temperature. Installation is built in 1993, compressor manufactured in 2003.
  1993 / 2003   More information
Bitzer/Searle/GEA   complete freezing plant, type of refrigerant: R404A/All Freon   150 kW   Used complete Bitzer/ Searle/GEA freezing installation/plant. This in very good condition complete freezing installation is composed of the following main components: • Bitzer screw package consists of 3 pieces Bitzer screw compressor type HSN6451-40-40p Eco connected to a closed intercooler (plate type) Oil separator Horizontal liquid receiver Suction manifold with suction filter High/low pressure gauges with all necessary safety devices Switch box • 4 pieces Searle/GEA one-sided blowing cooling-/freezing evaporators type SM162-66-A3-HGDD, each with air volume 7,24m3/s, fin spacing 6mm, hot gas defrost • 1 piece Searle/GEA one-sided blowing cooling-/freezing evaporator type KMe140-6-HGDD, with air volume 2,93m3/s, fin spacing 6mm, hot gas defrost • 1 piece Searle/GEA air-cooled condenser type MEC244-AL N604D • Complete control cabinet Mentioned cooling capacity of 150kW is with the refrigerant R404 at -30°C/+40°C with eco. Cooling capacity at -32°C/+35°C is 100kW.
  2011   More information
Bitzer/Goedhart   used freeze- and cold store installation, type of refrigerant: R404A/507   246 kW   Used in very good maintained condition: complete Bitzer/Goedhart cool/freeze installation consisting of the following main components; 1 x Bitzer unit for outside use with built in 1 x Bitzer central unit with 4 pieces 6H 25.2Y compressors (capacity control 0-33%-66%-100%) with an oil flow-back system and oil floaters on the carters of the compressors. Separately is delivered a Profroid air-cooled condenser type C7AH 10 MD4-12 PS (528 kW at DT15 K) with 10 ventilators. Switchboard cabinet with the complete control system. Furthermore, this cool/freeze installation is equipped with 4 pieces Goedhart PLK evaporators 21 kW ∆T 8 at an evaporating temperature of -10°C and with 2 pieces Woods ventilators of each 0,83 kW and 6 pieces PLK evaporators 31,5 kW ∆ 8-10°C with 3 pieces ventilators of 0,83 kW each. Complete hotgas defrosting set. If desired we can can also supply these evaporators with electrical defrost. Mentioned cooling capacity is with the refrigerant R404 at -10°C evaporating and +40°C condensing. Freezing capacity at -30°C evaporating is 104 kW. Cooling capacity: At -10°C evaporating temperature 246 kW / at -30°C evaporating temperature 104 kW.
  2004   More information
Bitzer / Heplman   used cooling installation, type of refrigerant: R507   373 kW   Used complete Bitzer / Helpman cooling installation for processing rooms and or corridors. This in very good maintained condition cooling installation consists of the following main components: • Bitzer cooling plant (built in a 10 ft container for outdoor installation), equipped with 3 pieces 6F-50.2Y compressors, oil separator, switch-board, liquid tank • Helpman / Alfa-Laval air-cooled condenser type HTC-100-253-410-CT-400V • 14 pieces Helpman double-sided evaporators type Thor-D-436-7-L-42 / 5-220V • P&ID drawing and the necessary certificates Mentioned cooling capacity is at an evaporating temperature of 0 ° C.
  2005   More information
Bitzer / Goedhart   used cooling installation, type of refrigerant: R507   435 kW   Used complete Bitzer / Goedhart cooling installation for processing rooms and or corridors. This in very good maintained condition cooling installation consists of the following main components: • Bitzer cooling plant (built in a 10 ft isolated container for outdoor installation), equipped with 3 pieces 6F-50.2Y compressors, oil separator, switch-board • Air-cooled condenser • 13 pieces Goedhart double-sided evaporators, type DVS 42636 Mentioned cooling capacity is at +4°C/+40°C.
  2002   More information